Key electrical specs
Usable capacity: 12.5 kWh.
Nominal voltage: 51.2 V, voltage range 44.8–57.6 V.
Nominal capacity: 250 Ah.
Recommended charge/discharge current: ≤150 A continuous.
Max charge & discharge current: 200 A for 15 s.
Max output power: 7 500 W, recommended continuous output up to 10 000 W in the family spec, though typically run around 5–7.5 kW in home systems.
Chemistry, life and environment
Chemistry: LiFePO₄ (lithium iron phosphate) for high safety, deep cycling and long life.
Depth of discharge: ≥95% DOD supported.
Cycle life: ≥6 000 cycles at 25 °C, 80% DOD.
Operating temperature: discharge −20 °C to +55 °C, charge 0 °C to +55 °C.
Integration and physical details
BMS & comms: built‑in smart BMS with CAN & RS485 for integration with compatible inverters and monitoring systems.
Parallel connection: 1–6 modules in parallel (up to 75 kWh total).
Typical enclosure: indoor wall‑mount/stackable cabinet, IP21 class for the FLA series.
Typical use: residential and small‑business hybrid or off‑grid systems needing a single ≈10–12 kWh usable block, expandable when larger storage is required.