Key electrical specs
Energy: 10.5 kWh.
Operating voltage range: 44.8–57.6 V (nominal 51.2 V).
Capacity: 205 Ah.
Depth of discharge: ≥95% DOD.
Current, power and lifetime
Recommended charge/discharge current: typically around 80–100 A for continuous use in this series.
Max charge/discharge current: 150–200 A for 15 s (FLB 48 V family spec).
Cycle life: ≥6 000 cycles at 25 °C, 80% DOD.
Integration, safety and use
Scalability: up to 15 units in parallel (157.5 kWh total).
Communications: CAN & RS485 for integration with compatible hybrid inverters and monitoring platforms.
Safety: built‑in aerosol fire extinguisher, smart BMS, and protections for over‑/under‑voltage, over‑current, short‑circuit and over‑temperature.
Typical applications: 48 V hybrid/off‑grid systems needing a mid‑size ~10 kWh block for whole‑home or small‑business loads, with room to scale up later.