Core power specs
Rated output: 5 000 VA / 4 000 W, single‑phase, nominal DC input 48 V.
AC input: dual‑voltage port 110 V / 220 V AC with wide input windows of about 80–140 V / 90–280 V AC and automatic transfer/bypass.
Efficiency: inverter/line efficiency up to 95%, suitable for continuous operation with mixed household loads.
PV, charging and battery
Built‑in MPPT: integrated MPPT solar charge controller for direct PV connection (48 V system), communicating with Felicity MPPT ecosystem where used together.
Charging: adjustable and higher charging current (up to around 170 A total across models in the IVPA series; IVPA5048 is typically in the 100–170 A range), supporting fast charging for larger banks.
Battery compatibility: 48 V lead‑acid and lithium banks, with seamless bypass charging and AC charging even when the inverter is powered off.
Features and ideal use
Functions: 3‑in‑1 hybrid (inverter + MPPT solar charger + AC charger), intelligent protection (overload, short‑circuit, over‑temperature, over/under‑voltage) and higher‑class safety design.
Monitoring: LCD/LED interface plus communication with Felicity MPPT controllers for coordinated solar‑battery management.
Ideal applications: complete home or small‑business systems on 48 V, powering fridges/freezers, pumps, electronics and general plugs from solar, batteries and grid/generator with automatic source management